A Villa Spa in Abu Dhabi: What the Drawings Must Show
Updated: 20 November 2026

Short answer: a villa spa in Abu Dhabi needs one drawing set for the whole spa wing, not one per room. It shows six things: a plan of the wing with every door swing, glass panel and plant position; a section through ceilings and voids; an electrical sheet with each room's circuit; a water and drain sheet; a cooling and extract sheet that keeps the villa's air apart from the hot rooms; and details for glass, timber, mosaic and the terrace edge. Sauna Dekor Spa Solutions checks the set sheet by sheet before manufacturing, because in a villa a missing line is found only when the ceiling is closed.
The rooms are the usual mix: a sauna at 80–100 °C, a steam room at 40–50 °C at close to 100 % relative humidity, a cold plunge we build for water temperatures from 2 to 15 °C, and showers between them.
What must the plan show?
On the drawing: the whole wing at one scale, with inside dimensions of each room, door widths and swings, the shower positions between rooms, the plant room or cupboard, and the route from the villa entrance to the wing with the largest glass panel drawn along it.
If it is missing: the glass front is made to the room and then cannot turn the corner of the stair, or the steam room door opens into the path of a wet shower.
What must the section show?
On the drawing: a cut through each room showing its ceiling height, the void above it, the villa's air-conditioning ducts in that void, the steam room ceiling slope, the insulation and vapour layers of the sauna, and the floor build-up with its falls.
If it is missing: an AC duct runs above the steam room ceiling and drips, or the sauna ceiling is set at the villa's ceiling height and the upper bench ends up too close to it.
What must the electrical sheet show?
On the drawing: a separate circuit from the board for the sauna heater, the steam generator, the plunge chiller and the lighting, each with its protection and isolator; the board's spare capacity checked against the total; the control panel positions; and the drivers for wet-room lights placed outside the wet rooms.
If it is missing: the heater shares a circuit with the kitchen, the board turns out full on the day the electrician connects the chiller, or a driver sits in the steam room ceiling.

What must the water and drain sheet show?
On the drawing: the water feed to the steam generator and the plunge with valves, the softener on the incoming line, the generator's drain, the plunge overflow and empty-out, a floor drain in every wet room and in the plant room, and the falls to each drain.
If it is missing: the generator has no drain within reach, the plunge has nowhere to empty, or the shower floor falls towards the sauna door.
What must the cooling and extract sheet show?
On the drawing: which rooms are on the villa's air-conditioning and which are not; the sauna's own supply and exhaust vents; the steam room sealed from the cooled ceiling; the plant room's extract to outside; and where the chiller rejects its heat.
If it is missing: cooled air is ducted into the sauna and it never reaches temperature, or the chiller sits in a closed room and stops on a summer afternoon.
What must the details show?
On the drawing: the glass front with its frame, door and how it meets the floor; timber species and bench layout; the mosaic or stone in the steam room with its corners and bench edge; the threshold between the wing and any terrace, with sand and dust in mind; and access panels for every sensor and valve.
If it is missing: glass is ordered without the door handing, the bench edge in the steam room is left square, or a terrace door brings sand straight onto a wet floor.
Sheet check table
| Sheet | What it must show | Who draws it |
|---|---|---|
| Plan | Wing layout, doors, glass, plant, delivery route | Architect with our layout |
| Section | Ceilings, voids, ducts, slopes, insulation, floor falls | Us with the architect |
| Electrical | Circuits, protection, isolators, board capacity, drivers | Electrical engineer from the makers' data |
| Water and drain | Feeds, softener, drains, overflow, falls | Plumbing engineer with us |
| Cooling and extract | AC zones, sauna vents, sealed steam ceiling, plant extract | MEP engineer |
| Details | Glass, timber, mosaic, thresholds, access panels | Us |
The villa spas we build in the city are on our villa spa in Abu Dhabi page.
Frequently asked questions
Does every room need its own drawings?
Each room needs its own section and details, but the plan and services sheets cover the whole wing so the rooms and plant fit together.
Who checks the set?
We do, against each equipment maker's installation data, and we return marked-up sheets to the architect and MEP engineer.
Why does glass appear on the electrical and cooling sheets?
Glass changes the heater load and the sun load on the room. The heater maker's rule for glass is applied when the heater is chosen.
Can drawing start before the equipment is chosen?
The plan can. The section, electrical and cooling sheets wait for the makers' data.
What warranty is given?
24 months on workmanship and manufacturing, 24 months manufacturer's warranty on electrical and mechanical equipment, and 5 years on structure and waterproofing, on every project.
Further reading
- Architectural drawing, Wikipedia
- Shop drawing, Wikipedia
- Vapor barrier, Wikipedia
- Residual-current device, Wikipedia
About the author. Sauna Dekor Spa Solutions · sauna, steam room, hammam and pool manufacturer since 1987 · 40 years of manufacturing in Istanbul · team of 19 · TS EN ISO 9001:2015 · 5,000+ projects in 41+ countries, including 577+ hotel and resort projects · 732 documented references in 32 countries and territories.